Some users experience the Follow outlets no longer being switched. This can be caused by very high inrush currents from the connected Follow devices, which greatly exceed the relay's maximum load capacity and cause the switching contacts to weld together.
In many cases, the switching contacts can be separated again by vibrations (tapping), temporarily restoring operation. However, if the configuration of the Follow devices is not changed, the problem usually reoccurs quickly.
Background:
Our automatic power strips, including the relays used in them, are designed for continuous loads with currents of 16A. End devices with a grounded plug must not draw more current. However, some end devices exceed this limit many times over at the moment they are switched on. The current draw can rise to 50A or more for a fraction of a second, for example. These high currents can cause the switching contacts in the relay to weld together—the relay then no longer switches off.
Experience has shown that the problem occurs more frequently with end devices that have switching power supplies. Nowadays, these can be installed in almost anything, such as PCs, monitors, printers, external hard drives, powered speakers, etc. Which products specifically cause such problems also depends on whether the manufacturers of the end devices have taken appropriate measures to prevent excessive inrush currents. Unfortunately, this cannot be determined from any datasheet or nameplate. We have optimized our automatic power strips in this regard by using special relays for pulse loads of up to 80A. As a result, the problem occurs much less frequently.